Appendix cC.1 SWITCH SETTINGS FOR C.Itoh PRINTERS F10-40P Daisywheel
Switch 40 Switch 41
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 9 10
C O O C O O C C O O C O C O O C O O
1550 Dot Matrix
Switch 1 Switch 2
Normal 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
O C O O O C C O O O O O O C O O
Graphics 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
C C O O O C C O O O O O O C O C
Where O = Open and C = Closed
It is possible to demonstrate the graphics capability of the C.Itoh 1550 printer from the graphics demonstration disc. This is done by typing "P" when the graphics routine required to be printed is being displayed on the VDU, eg. pie charts. This causes the graphics program to produce pixel dump to the printer. In order to achieve this the following adjustments must be made to the printer and cable 1. The switches on the printer should be set as follows:
SW 1 1 2 3 4 5 6 7 8
C C O O O C C C
SW 2 1 2 3 4 5 6 7 8
O O O O O C O C
where C = Closed and O = Open
C.2 Parallel Printer Cables
Parallel Cable for Paper Tiger
Sirius Printer
1 --------------- 3
2 --------------- 14
3 --------------- 13
4 --------------- 12
5 --------------- 11
6 --------------- 10
7 --------------- 9
8 --------------- 15
10 --------------- 22
11 --------------- 19
14 --------------- 7
17 --------------- 1
Parallel Cable for Olivetti Bytewriter
Sirius Printer
1 --------------- 1
2 --------------- 3
3 --------------- 5
4 --------------- 7
5 --------------- 9
6 --------------- 11
7 --------------- 13
8 --------------- 15
11 --------------- 17
14 --------------- 2
16 --------------- 4
Parallel Cable for Crown Ranier Typewriter
Sirius Printer
1
1 --------------- 2
3
2 --------------- 4
10 --------------- 5
3 --------------- 6
11 --------------- 7
4 --------------- 8
9 --------------- 9
5 --------------- 10
8 --------------- 11
6 --------------- 12
7 --------------- 13
14 --------------- 14
Parallel Cable for Trend Com-200
Sirius Printer
1 --------------- 8
2 --------------- 10
3 --------------- 11
4 --------------- 12
5 --------------- 13
6 --------------- 14
7 --------------- 15
8 --------------- 16
9 --------------- 17
11 --------------- 2
20 --------------- 1
21 --------------- 5
Parallel Cable for IBM
Sirius Printer
1 --------------- 1
2 --------------- 2
3 --------------- 3
4 --------------- 4
5 --------------- 5
6 --------------- 6
7 --------------- 7
8 --------------- 8
9 --------------- 9
10 --------------- 10
11 --------------- 11
13 --------------- 13
15 --------------- 16
16 --------------- 12
24 --------------- 24
25 --------------- 25
Parallel Cable for Epson MX80
Sirius Printer
1 --------------- 1
2 --------------- 2
3 --------------- 3
4 --------------- 4
5 --------------- 5
6 --------------- 6
7 --------------- 7
8 --------------- 8
9 --------------- 9
10 --------------- 10
11 --------------- 11
17 --------------- 17
19 --------------- 19
20 --------------- 20
21 --------------- 21
22 --------------- 22
Parallel Cable for Oki Microline 84
1 --------------- 1
2 --------------- 2
3 --------------- 3
4 --------------- 4
5 --------------- 5
6 --------------- 6
7 --------------- 7
8 --------------- 8
9 --------------- 9
27 ---|
10 --------------- 10
11 --------------- 11
17 --------------- 17
Switch Settings:
1 2 3 4 5 6 7 8
C C C C O C C C
C.3 Serial Printer Cables
Serial Cable for QUME Sprint 5, DTC-300, Epson MX80, Datasouth
DS180
Sirius Printer
1 --------------- 1
2 --------------- 3
3 --------------- 2
5 --------------- 20
7 --------------- 7
20 --------------- 5
Serial Cable for Diablo 630
Sirius Printer
1 --------------- 1
2 --------------- 3
3 --------------- 2
5 --------------- 20
7 --------------- 7
8 --------------- 5
20 ---| |---- 6
|---- 8
Serial Cable for Mannesman-Tally (1805) and Anadex
Sirius Printer
1 --------------- 1
2 --------------- 3
3 --------------- 2
5 --------------- 19
7 --------------- 7
8 ----|
20 ----|
Serial Cable for Mannesman Tally MT-140 & MT-180
Sirius Tally
2 ---------------- 3
3 ---------------- 2
5 ---------------- 11
7 ---------------- 7
11 ---------------- 5
8 ----|-------|--- 8
20 ----| |--- 20
Serial Cable for NEC Spinwriter 5520
Sirius Printer
2 --------------- 3
3 --------------- 2
7 --------------- 7
5 --------------- 19
|------ 25
|------ 6
|------ 8
Serial Cable for Oki Microline - Series (80/82A)
Sirius Printer
1 --------------- 1
2 --------------- 3
7 --------------- 7
5 --------------- 11
|------ 6
|------ 8
|------ 20
SW1 (Busy polarity)
OFF
SW2 SW4 (1200 Baud)
ON ON
SW6 (No Parity)
OFF
Serial Cable for Qume Sprint 9
Sirius Printer
1 --------------- 1
2 --------------- 3
3 --------------- 2
7 --------------- 7
5 --------------- 20
|------ 4
|------ 6
|------ 8
A-1 A-2 A-3 (4800 baud) A-4 (Self Test OFF)
OFF ON ON OFF
A-5 (H/duplex) B-7 B-8 (H/ware handshake) C-3(WPS OFF)
OFF OFF OFF OFF
Serial Cable for Olympia 103
Sirius Printer
1 --------------- 1
2 --------------- 3
3 --------------- 2
7 --------------- 7
5 --------------- 4
Switch Settings for 4800 baud
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 9 10
C C C O C C O O O C O C O O C C O O
Serial Cable for TRD 170
Sirius Printer
1 --------------- 1
2 --------------- 3
3 --------------- 2
5 --------------- 4
7 --------------- 7
Serial Cable for IDS 560
Sirius Printer
1 --------------- 1
2 --------------- 3
3 --------------- 2
5 --------------- 20
7 --------------- 7
8 -----|
20 -----|
Serial Cable for Lear System 300
Sirius Printer
1 --------------- 1
2 --------------- 3
3 --------------- 2
7 --------------- 7
5 --------------- 14
|------ 6
|------ 8
|------ 20
Serial Cable for Brother HR1
Sirius Printer
1 --------------- 1
2 --------------- 3
3 --------------- 2
7 --------------- 7
5 --------------- 20
20 --------------- 6
|------ 8
Serial Cable for Toshiba
Sirius Toshiba
1 --------------- 1
2 --------------- 3
3 --------------- 2
|-- 5
5 --------------- 20
7 --------------- 7
Serial Cable for Texas 810 with D.N.B. option
Sirius Texas
1 --------------- 1
2 --------------- 3
3 --------------- 2
7 --------------- 7
5 --------------- 20
|--- 6
|--- 8
|--- 9
All contents of this website (including text, images, design, and presentation) are Copyright � 1999-2005, |